Getting information about Sinergym environments
Sinergym offers different ways to access background components of the available environments.
This notebook will show how to use them.
[1]:
import gymnasium as gym
import numpy as np
import sinergym
from sinergym.utils.common import export_schedulers_to_excel
Schedulers information
Buildings have a set of schedulers that control the building’s actuators according to predefined rules. In addition to the information available in the log files generated by EnergyPlus, you can consult Sinergym’s reading of the building to see how these schedulers affect the building.
Schedulers information is extracted as a Python dictionary. Sinergym can export that information to a spreadsheet.
To do this, simply load the environment and follow the next steps:
[2]:
from pprint import pprint
env = gym.make('Eplus-demo-v1')
schedulers = env.get_wrapper_attr('schedulers')
pprint(schedulers)
#==============================================================================================#
[ENVIRONMENT] (INFO) : Creating Gymnasium environment.
[ENVIRONMENT] (INFO) : Name: demo-v1
#==============================================================================================#
[MODEL] (INFO) : Working directory created: /workspaces/sinergym/examples/demo-v1-res1
[MODEL] (INFO) : Model Config is correct.
[MODEL] (INFO) : Building model Output:Variable updated with defined variable names.
[MODEL] (INFO) : Updated building model Output:Meter with meter names.
[MODEL] (INFO) : Building configuration: runperiod updated to {'start_day': 1, 'start_month': 1, 'start_year': 1991, 'end_day': 1, 'end_month': 3, 'end_year': 1991, 'start_weekday': 1, 'n_steps_per_hour': 1}
[MODEL] (INFO) : Updated episode length (seconds): 5184000.0
[MODEL] (INFO) : Updated timestep size (seconds): 3600.0
[MODEL] (INFO) : Updated timesteps per episode: 1440
[MODEL] (INFO) : Runperiod established.
[MODEL] (INFO) : Episode length (seconds): 5184000.0
[MODEL] (INFO) : timestep size (seconds): 3600.0
[MODEL] (INFO) : timesteps per episode: 1440
[REWARD] (INFO) : Reward function initialized.
[ENVIRONMENT] (INFO) : Environment created successfully.
{'ActSchd': {'SPACE1-1 People 1': {'field_name': 'activity_level_schedule_name',
'table_name': 'People'},
'SPACE2-1 People 1': {'field_name': 'activity_level_schedule_name',
'table_name': 'People'},
'SPACE3-1 People 1': {'field_name': 'activity_level_schedule_name',
'table_name': 'People'},
'SPACE4-1 People 1': {'field_name': 'activity_level_schedule_name',
'table_name': 'People'},
'SPACE5-1 People 1': {'field_name': 'activity_level_schedule_name',
'table_name': 'People'},
'Type': 'Any Number'},
'ActivitySch': {'Type': 'Any Number'},
'AirVelocitySch': {'SPACE1-1 People 1': {'field_name': 'air_velocity_schedule_name',
'table_name': 'People'},
'SPACE2-1 People 1': {'field_name': 'air_velocity_schedule_name',
'table_name': 'People'},
'SPACE3-1 People 1': {'field_name': 'air_velocity_schedule_name',
'table_name': 'People'},
'SPACE4-1 People 1': {'field_name': 'air_velocity_schedule_name',
'table_name': 'People'},
'SPACE5-1 People 1': {'field_name': 'air_velocity_schedule_name',
'table_name': 'People'},
'Type': 'Any Number'},
'BasinHeaterSched': {'Main Cooling Coil 1': {'field_name': 'basin_heater_operating_schedule_name',
'table_name': 'Coil:Cooling:DX:TwoSpeed'},
'Type': 'On/Off'},
'Clg-SetP-Sch': {'CoolingSetpoint': {'field_name': 'setpoint_temperature_schedule_name',
'table_name': 'ThermostatSetpoint:SingleCooling'},
'DualSetPoint': {'field_name': 'cooling_setpoint_temperature_schedule_name',
'table_name': 'ThermostatSetpoint:DualSetpoint'},
'Type': 'Temperature'},
'ClothingSch': {'Type': 'Any Number'},
'CoolingCoilAvailSched': {'DX Cooling Coil System 1': {'field_name': 'availability_schedule_name',
'table_name': 'CoilSystem:Cooling:DX'},
'Main Cooling Coil 1': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Cooling:DX:TwoSpeed'},
'Type': 'Fraction'},
'EQUIP-1': {'SPACE1-1 ElecEq 1': {'field_name': 'schedule_name',
'table_name': 'ElectricEquipment'},
'SPACE2-1 ElecEq 1': {'field_name': 'schedule_name',
'table_name': 'ElectricEquipment'},
'SPACE3-1 ElecEq 1': {'field_name': 'schedule_name',
'table_name': 'ElectricEquipment'},
'SPACE4-1 ElecEq 1': {'field_name': 'schedule_name',
'table_name': 'ElectricEquipment'},
'SPACE5-1 ElecEq 1': {'field_name': 'schedule_name',
'table_name': 'ElectricEquipment'},
'Type': 'Fraction'},
'FanAvailSched': {'Supply Fan 1': {'field_name': 'availability_schedule_name',
'table_name': 'Fan:VariableVolume'},
'Type': 'Fraction',
'VAV Sys 1 Avail': {'field_name': 'schedule_name',
'table_name': 'AvailabilityManager:Scheduled'}},
'Htg-SetP-Sch': {'DualSetPoint': {'field_name': 'heating_setpoint_temperature_schedule_name',
'table_name': 'ThermostatSetpoint:DualSetpoint'},
'HeatingSetpoint': {'field_name': 'setpoint_temperature_schedule_name',
'table_name': 'ThermostatSetpoint:SingleHeating'},
'Type': 'Temperature'},
'INFIL-SCH': {'SPACE1-1 Infil 1': {'field_name': 'schedule_name',
'table_name': 'ZoneInfiltration:DesignFlowRate'},
'SPACE2-1 Infil 1': {'field_name': 'schedule_name',
'table_name': 'ZoneInfiltration:DesignFlowRate'},
'SPACE3-1 Infil 1': {'field_name': 'schedule_name',
'table_name': 'ZoneInfiltration:DesignFlowRate'},
'SPACE4-1 Infil 1': {'field_name': 'schedule_name',
'table_name': 'ZoneInfiltration:DesignFlowRate'},
'SPACE5-1 Infil 1': {'field_name': 'schedule_name',
'table_name': 'ZoneInfiltration:DesignFlowRate'},
'Type': 'Fraction'},
'LIGHTS-1': {'SPACE1-1 Lights 1': {'field_name': 'schedule_name',
'table_name': 'Lights'},
'SPACE2-1 Lights 1': {'field_name': 'schedule_name',
'table_name': 'Lights'},
'SPACE3-1 Lights 1': {'field_name': 'schedule_name',
'table_name': 'Lights'},
'SPACE4-1 Lights 1': {'field_name': 'schedule_name',
'table_name': 'Lights'},
'SPACE5-1 Lights 1': {'field_name': 'schedule_name',
'table_name': 'Lights'},
'Type': 'Fraction'},
'Min OA Sched': {'OA Controller 1': {'field_name': 'minimum_outdoor_air_schedule_name',
'table_name': 'Controller:OutdoorAir'},
'Type': 'Fraction'},
'Min OARequirements Sched': {'Type': 'Any Number',
'ZoneMinOARequirements': {'field_name': 'outdoor_air_schedule_name',
'table_name': 'DesignSpecification:OutdoorAir'}},
'OCCUPY-1': {'SPACE1-1 People 1': {'field_name': 'number_of_people_schedule_name',
'table_name': 'People'},
'SPACE2-1 People 1': {'field_name': 'number_of_people_schedule_name',
'table_name': 'People'},
'SPACE3-1 People 1': {'field_name': 'number_of_people_schedule_name',
'table_name': 'People'},
'SPACE4-1 People 1': {'field_name': 'number_of_people_schedule_name',
'table_name': 'People'},
'SPACE5-1 People 1': {'field_name': 'number_of_people_schedule_name',
'table_name': 'People'},
'Type': 'Fraction'},
'PlenumClg-SetP-Sch': {'PlenumCoolingSetpoint': {'field_name': 'setpoint_temperature_schedule_name',
'table_name': 'ThermostatSetpoint:SingleCooling'},
'Type': 'Temperature'},
'PlenumHtg-SetP-Sch': {'PlenumHeatingSetpoint': {'field_name': 'setpoint_temperature_schedule_name',
'table_name': 'ThermostatSetpoint:SingleHeating'},
'Type': 'Temperature'},
'ReheatCoilAvailSched': {'Main heating Coil 1': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Heating:Electric'},
'SPACE1-1 VAV Reheat': {'field_name': 'availability_schedule_name',
'table_name': 'AirTerminal:SingleDuct:VAV:Reheat'},
'SPACE1-1 Zone Coil': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Heating:Electric'},
'SPACE2-1 VAV Reheat': {'field_name': 'availability_schedule_name',
'table_name': 'AirTerminal:SingleDuct:VAV:Reheat'},
'SPACE2-1 Zone Coil': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Heating:Electric'},
'SPACE3-1 VAV Reheat': {'field_name': 'availability_schedule_name',
'table_name': 'AirTerminal:SingleDuct:VAV:Reheat'},
'SPACE3-1 Zone Coil': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Heating:Electric'},
'SPACE4-1 VAV Reheat': {'field_name': 'availability_schedule_name',
'table_name': 'AirTerminal:SingleDuct:VAV:Reheat'},
'SPACE4-1 Zone Coil': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Heating:Electric'},
'SPACE5-1 VAV Reheat': {'field_name': 'availability_schedule_name',
'table_name': 'AirTerminal:SingleDuct:VAV:Reheat'},
'SPACE5-1 Zone Coil': {'field_name': 'availability_schedule_name',
'table_name': 'Coil:Heating:Electric'},
'Type': 'Fraction'},
'Seasonal Reset Supply Air Temp Sch': {'Type': 'Temperature'},
'ShadeTransSch': {'Main South Overhang': {'field_name': 'transmittance_schedule_name',
'table_name': 'Shading:Zone:Detailed'},
'South Door Overhang': {'field_name': 'transmittance_schedule_name',
'table_name': 'Shading:Zone:Detailed'},
'Type': 'Fraction'},
'WorkEffSch': {'SPACE1-1 People 1': {'field_name': 'work_efficiency_schedule_name',
'table_name': 'People'},
'SPACE2-1 People 1': {'field_name': 'work_efficiency_schedule_name',
'table_name': 'People'},
'SPACE3-1 People 1': {'field_name': 'work_efficiency_schedule_name',
'table_name': 'People'},
'SPACE4-1 People 1': {'field_name': 'work_efficiency_schedule_name',
'table_name': 'People'},
'SPACE5-1 People 1': {'field_name': 'work_efficiency_schedule_name',
'table_name': 'People'},
'Type': 'Fraction'},
'Zone Control Type Sched': {'SPACE1-1 Control': {'field_name': 'control_type_schedule_name',
'table_name': 'ZoneControl:Thermostat'},
'SPACE2-1 Control': {'field_name': 'control_type_schedule_name',
'table_name': 'ZoneControl:Thermostat'},
'SPACE3-1 Control': {'field_name': 'control_type_schedule_name',
'table_name': 'ZoneControl:Thermostat'},
'SPACE4-1 Control': {'field_name': 'control_type_schedule_name',
'table_name': 'ZoneControl:Thermostat'},
'SPACE5-1 Control': {'field_name': 'control_type_schedule_name',
'table_name': 'ZoneControl:Thermostat'},
'Type': 'Control Type'}}
We can export this data to a spreadsheet:
[3]:
export_schedulers_to_excel(schedulers=schedulers,path='./example.xlsx')
Environment properties
Some environment features are created in the Gymnasium interface layer, but more information is managed in the back-end.
Sinergym environments have several properties to consult this information. For in-depth details, visit the documentation. However, here are some examples.
[4]:
print('What is all the variables names which conform my Gymnasium observation?: {}'.format(
env.get_wrapper_attr('observation_variables')))
print('What is all the variables names which conform my Gymnasium action?: {}'.format(
env.get_wrapper_attr('action_variables')))
print('Is there an episode executing?: {}'.format(
env.get_wrapper_attr('is_running')))
print('What is the episode run period?: {}'.format(
env.get_wrapper_attr('runperiod')))
print('Episode length in seconds?: {}'.format(
env.get_wrapper_attr('episode_length')))
print('How many steps have an episode?: {}'.format(
env.get_wrapper_attr('timestep_per_episode')))
print('How often do steps changed?: {}'.format(
env.get_wrapper_attr('step_size')))
print('What are the available zones?: {}'.format(
env.get_wrapper_attr('zone_names')))
print('Where is the output path of Sinergym environment?: {}'.format(
env.get_wrapper_attr('workspace_path')))
print('Where is the building used?: {}'.format(
env.get_wrapper_attr('building_path')))
print('Where is the weather used?: {}'.format(
env.get_wrapper_attr('weather_path')))
print('Is the action space discrete?: {}'.format(
env.get_wrapper_attr('is_discrete')))
What is all the variables names which conform my Gymnasium observation?: ['month', 'day_of_month', 'hour', 'outdoor_temperature', 'htg_setpoint', 'clg_setpoint', 'air_temperature', 'air_humidity', 'HVAC_electricity_demand_rate']
What is all the variables names which conform my Gymnasium action?: ['Heating_Setpoint_RL', 'Cooling_Setpoint_RL']
Is there an episode executing?: False
What is the episode run period?: {'start_day': 1, 'start_month': 1, 'start_year': 1991, 'end_day': 1, 'end_month': 3, 'end_year': 1991, 'start_weekday': 1, 'n_steps_per_hour': 1}
Episode length in seconds?: 5184000.0
How many steps have an episode?: 1440
How often do steps changed?: 3600.0
What are the available zones?: ['PLENUM-1', 'SPACE1-1', 'SPACE2-1', 'SPACE3-1', 'SPACE4-1', 'SPACE5-1']
Where is the output path of Sinergym environment?: /workspaces/sinergym/examples/demo-v1-res1
Where is the building used?: /workspaces/sinergym/sinergym/data/buildings/5ZoneAutoDXVAV.epJSON
Where is the weather used?: /workspaces/sinergym/sinergym/data/weather/USA_PA_Pittsburgh-Allegheny.County.AP.725205_TMY3.epw
Is the action space discrete?: False
Handlers information
Similarly, we can consult the actuators, variables, and meters available in the environment, along with those we are specifically controlling and observing in our environment.
You can consult them as follows:
[5]:
print('Available Handlers: {}'.format(
env.get_wrapper_attr('available_handlers')))
print('Controlled actuators: {}'.format(
env.get_wrapper_attr('actuator_handlers')))
print('Observed variables: {}'.format(env.get_wrapper_attr('var_handlers')))
print('Observed meters: {}'.format(env.get_wrapper_attr('meter_handlers')))
Available Handlers: None
Controlled actuators: None
Observed variables: None
Observed meters: None
As can be observed, the information is not displayed. This is due to internal particularities of the EnergyPlus API.
To make this information available, we need to call reset
first:
[6]:
env.reset()
print('Available Handlers: {}'.format(
env.get_wrapper_attr('available_handlers')))
print('Controlled actuators: {}'.format(
env.get_wrapper_attr('actuator_handlers')))
print('Observed variables: {}'.format(env.get_wrapper_attr('var_handlers')))
print('Observed meters: {}'.format(env.get_wrapper_attr('meter_handlers')))
#----------------------------------------------------------------------------------------------#
[ENVIRONMENT] (INFO) : Starting a new episode.
[ENVIRONMENT] (INFO) : Episode 1: demo-v1
#----------------------------------------------------------------------------------------------#
[MODEL] (INFO) : Episode directory created.
[MODEL] (INFO) : Weather file USA_PA_Pittsburgh-Allegheny.County.AP.725205_TMY3.epw used.
[MODEL] (INFO) : Adapting weather to building model.
[ENVIRONMENT] (INFO) : Saving episode output path in /workspaces/sinergym/examples/demo-v1-res1/episode-1/output.
[SIMULATOR] (INFO) : handlers initialized.
[SIMULATOR] (INFO) : handlers are ready.
[SIMULATOR] (INFO) : System is ready.
[ENVIRONMENT] (INFO) : Episode 1 started.
Available Handlers: **ACTUATORS**
Actuator,Schedule:Compact,Schedule Value,ACTSCHD
Actuator,Schedule:Compact,Schedule Value,ACTIVITYSCH
Actuator,Schedule:Compact,Schedule Value,AIRVELOCITYSCH
Actuator,Schedule:Compact,Schedule Value,BASINHEATERSCHED
Actuator,Schedule:Compact,Schedule Value,CLG-SETP-SCH
Actuator,Schedule:Compact,Schedule Value,CLOTHINGSCH
Actuator,Schedule:Compact,Schedule Value,COOLINGCOILAVAILSCHED
Actuator,Schedule:Compact,Schedule Value,EQUIP-1
Actuator,Schedule:Compact,Schedule Value,FANAVAILSCHED
Actuator,Schedule:Compact,Schedule Value,HTG-SETP-SCH
Actuator,Schedule:Compact,Schedule Value,INFIL-SCH
Actuator,Schedule:Compact,Schedule Value,LIGHTS-1
Actuator,Schedule:Compact,Schedule Value,MIN OA SCHED
Actuator,Schedule:Compact,Schedule Value,MIN OAREQUIREMENTS SCHED
Actuator,Schedule:Compact,Schedule Value,OCCUPY-1
Actuator,Schedule:Compact,Schedule Value,PLENUMCLG-SETP-SCH
Actuator,Schedule:Compact,Schedule Value,PLENUMHTG-SETP-SCH
Actuator,Schedule:Compact,Schedule Value,REHEATCOILAVAILSCHED
Actuator,Schedule:Compact,Schedule Value,SEASONAL RESET SUPPLY AIR TEMP SCH
Actuator,Schedule:Compact,Schedule Value,SHADETRANSSCH
Actuator,Schedule:Compact,Schedule Value,WORKEFFSCH
Actuator,Schedule:Compact,Schedule Value,ZONE CONTROL TYPE SCHED
Actuator,Weather Data,Outdoor Dry Bulb,Environment
Actuator,Weather Data,Outdoor Dew Point,Environment
Actuator,Weather Data,Outdoor Relative Humidity,Environment
Actuator,Weather Data,Diffuse Solar,Environment
Actuator,Weather Data,Direct Solar,Environment
Actuator,Weather Data,Wind Speed,Environment
Actuator,Weather Data,Wind Direction,Environment
Actuator,Material,Surface Property Solar Absorptance,BR01
Actuator,Material,Surface Property Thermal Absorptance,BR01
Actuator,Material,Surface Property Visible Absorptance,BR01
Actuator,Material,Surface Property Solar Absorptance,CC03
Actuator,Material,Surface Property Thermal Absorptance,CC03
Actuator,Material,Surface Property Visible Absorptance,CC03
Actuator,Material,Surface Property Solar Absorptance,GP01
Actuator,Material,Surface Property Thermal Absorptance,GP01
Actuator,Material,Surface Property Visible Absorptance,GP01
Actuator,Material,Surface Property Solar Absorptance,GP02
Actuator,Material,Surface Property Thermal Absorptance,GP02
Actuator,Material,Surface Property Visible Absorptance,GP02
Actuator,Material,Surface Property Solar Absorptance,IN02
Actuator,Material,Surface Property Thermal Absorptance,IN02
Actuator,Material,Surface Property Visible Absorptance,IN02
Actuator,Material,Surface Property Solar Absorptance,IN46
Actuator,Material,Surface Property Thermal Absorptance,IN46
Actuator,Material,Surface Property Visible Absorptance,IN46
Actuator,Material,Surface Property Solar Absorptance,PW03
Actuator,Material,Surface Property Thermal Absorptance,PW03
Actuator,Material,Surface Property Visible Absorptance,PW03
Actuator,Material,Surface Property Solar Absorptance,RG01
Actuator,Material,Surface Property Thermal Absorptance,RG01
Actuator,Material,Surface Property Visible Absorptance,RG01
Actuator,Material,Surface Property Solar Absorptance,WD01
Actuator,Material,Surface Property Thermal Absorptance,WD01
Actuator,Material,Surface Property Visible Absorptance,WD01
Actuator,Material,Surface Property Solar Absorptance,WD10
Actuator,Material,Surface Property Thermal Absorptance,WD10
Actuator,Material,Surface Property Visible Absorptance,WD10
Actuator,Material,Surface Property Solar Absorptance,CP01
Actuator,Material,Surface Property Thermal Absorptance,CP01
Actuator,Material,Surface Property Visible Absorptance,CP01
Actuator,Material,Surface Property Solar Absorptance,MAT-CLNG-1
Actuator,Material,Surface Property Thermal Absorptance,MAT-CLNG-1
Actuator,Material,Surface Property Visible Absorptance,MAT-CLNG-1
Actuator,Material,Surface Property Solar Absorptance,MAT-FLOOR-1
Actuator,Material,Surface Property Thermal Absorptance,MAT-FLOOR-1
Actuator,Material,Surface Property Visible Absorptance,MAT-FLOOR-1
Actuator,Material,Surface Property Solar Absorptance,MAT-SB-U
Actuator,Material,Surface Property Thermal Absorptance,MAT-SB-U
Actuator,Material,Surface Property Visible Absorptance,MAT-SB-U
Actuator,People,Number of People,SPACE1-1 PEOPLE 1
Actuator,People,Number of People,SPACE2-1 PEOPLE 1
Actuator,People,Number of People,SPACE3-1 PEOPLE 1
Actuator,People,Number of People,SPACE4-1 PEOPLE 1
Actuator,People,Number of People,SPACE5-1 PEOPLE 1
Actuator,Lights,Electricity Rate,SPACE1-1 LIGHTS 1
Actuator,Lights,Electricity Rate,SPACE2-1 LIGHTS 1
Actuator,Lights,Electricity Rate,SPACE3-1 LIGHTS 1
Actuator,Lights,Electricity Rate,SPACE4-1 LIGHTS 1
Actuator,Lights,Electricity Rate,SPACE5-1 LIGHTS 1
Actuator,ElectricEquipment,Electricity Rate,SPACE1-1 ELECEQ 1
Actuator,ElectricEquipment,Electricity Rate,SPACE2-1 ELECEQ 1
Actuator,ElectricEquipment,Electricity Rate,SPACE3-1 ELECEQ 1
Actuator,ElectricEquipment,Electricity Rate,SPACE4-1 ELECEQ 1
Actuator,ElectricEquipment,Electricity Rate,SPACE5-1 ELECEQ 1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,MAIN SOUTH OVERHANG
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,MAIN SOUTH OVERHANG
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,Mir-MAIN SOUTH OVERHANG
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,Mir-MAIN SOUTH OVERHANG
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SOUTH DOOR OVERHANG
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SOUTH DOOR OVERHANG
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,Mir-SOUTH DOOR OVERHANG
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,Mir-SOUTH DOOR OVERHANG
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WALL-1PB
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WALL-1PB
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WALL-1PF
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WALL-1PF
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WALL-1PL
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WALL-1PL
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WALL-1PR
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WALL-1PR
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C1-1P
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C1-1P
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C2-1P
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C2-1P
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C3-1P
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C3-1P
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C4-1P
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C4-1P
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C5-1P
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C5-1P
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,TOP-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,TOP-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,FRONT-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,FRONT-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB12
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB12
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB14
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB14
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB15
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB15
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,F1-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,F1-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C1-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C1-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,DF-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,DF-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WF-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WF-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,RIGHT-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,RIGHT-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB21
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB21
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB23
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB23
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB25
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB25
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,F2-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,F2-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C2-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C2-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WR-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WR-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,BACK-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,BACK-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB32
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB32
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB34
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB34
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB35
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB35
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,F3-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,F3-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C3-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C3-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,DB-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,DB-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WB-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WB-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,LEFT-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,LEFT-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB41
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB41
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB43
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB43
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB45
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB45
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,F4-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,F4-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C4-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C4-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,WL-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,WL-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB51
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB51
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB52
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB52
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB53
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB53
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,SB54
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,SB54
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,F5-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,F5-1
Actuator,Surface,Interior Surface Convection Heat Transfer Coefficient,C5-1
Actuator,Surface,Exterior Surface Convection Heat Transfer Coefficient,C5-1
Actuator,Surface,Construction State,WALL-1PB
Actuator,Surface,Construction State,WALL-1PF
Actuator,Surface,Construction State,WALL-1PL
Actuator,Surface,Construction State,WALL-1PR
Actuator,Surface,Construction State,C1-1P
Actuator,Surface,Construction State,C2-1P
Actuator,Surface,Construction State,C3-1P
Actuator,Surface,Construction State,C4-1P
Actuator,Surface,Construction State,C5-1P
Actuator,Surface,Construction State,TOP-1
Actuator,Surface,Construction State,FRONT-1
Actuator,Surface,Construction State,SB12
Actuator,Surface,Construction State,SB14
Actuator,Surface,Construction State,SB15
Actuator,Surface,Construction State,F1-1
Actuator,Surface,Construction State,C1-1
Actuator,Surface,Construction State,DF-1
Actuator,Surface,Construction State,WF-1
Actuator,Surface,Construction State,RIGHT-1
Actuator,Surface,Construction State,SB21
Actuator,Surface,Construction State,SB23
Actuator,Surface,Construction State,SB25
Actuator,Surface,Construction State,F2-1
Actuator,Surface,Construction State,C2-1
Actuator,Surface,Construction State,WR-1
Actuator,Surface,Construction State,BACK-1
Actuator,Surface,Construction State,SB32
Actuator,Surface,Construction State,SB34
Actuator,Surface,Construction State,SB35
Actuator,Surface,Construction State,F3-1
Actuator,Surface,Construction State,C3-1
Actuator,Surface,Construction State,DB-1
Actuator,Surface,Construction State,WB-1
Actuator,Surface,Construction State,LEFT-1
Actuator,Surface,Construction State,SB41
Actuator,Surface,Construction State,SB43
Actuator,Surface,Construction State,SB45
Actuator,Surface,Construction State,F4-1
Actuator,Surface,Construction State,C4-1
Actuator,Surface,Construction State,WL-1
Actuator,Surface,Construction State,SB51
Actuator,Surface,Construction State,SB52
Actuator,Surface,Construction State,SB53
Actuator,Surface,Construction State,SB54
Actuator,Surface,Construction State,F5-1
Actuator,Surface,Construction State,C5-1
Actuator,Surface,View Factor To Ground,WALL-1PB
Actuator,Surface,Outdoor Air Drybulb Temperature,WALL-1PB
Actuator,Surface,Outdoor Air Wetbulb Temperature,WALL-1PB
Actuator,Surface,Outdoor Air Wind Speed,WALL-1PB
Actuator,Surface,Outdoor Air Wind Direction,WALL-1PB
Actuator,Surface,View Factor To Ground,WALL-1PF
Actuator,Surface,Outdoor Air Drybulb Temperature,WALL-1PF
Actuator,Surface,Outdoor Air Wetbulb Temperature,WALL-1PF
Actuator,Surface,Outdoor Air Wind Speed,WALL-1PF
Actuator,Surface,Outdoor Air Wind Direction,WALL-1PF
Actuator,Surface,View Factor To Ground,WALL-1PL
Actuator,Surface,Outdoor Air Drybulb Temperature,WALL-1PL
Actuator,Surface,Outdoor Air Wetbulb Temperature,WALL-1PL
Actuator,Surface,Outdoor Air Wind Speed,WALL-1PL
Actuator,Surface,Outdoor Air Wind Direction,WALL-1PL
Actuator,Surface,View Factor To Ground,WALL-1PR
Actuator,Surface,Outdoor Air Drybulb Temperature,WALL-1PR
Actuator,Surface,Outdoor Air Wetbulb Temperature,WALL-1PR
Actuator,Surface,Outdoor Air Wind Speed,WALL-1PR
Actuator,Surface,Outdoor Air Wind Direction,WALL-1PR
Actuator,Surface,View Factor To Ground,TOP-1
Actuator,Surface,Outdoor Air Drybulb Temperature,TOP-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,TOP-1
Actuator,Surface,Outdoor Air Wind Speed,TOP-1
Actuator,Surface,Outdoor Air Wind Direction,TOP-1
Actuator,Surface,View Factor To Ground,FRONT-1
Actuator,Surface,Outdoor Air Drybulb Temperature,FRONT-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,FRONT-1
Actuator,Surface,Outdoor Air Wind Speed,FRONT-1
Actuator,Surface,Outdoor Air Wind Direction,FRONT-1
Actuator,Surface,View Factor To Ground,DF-1
Actuator,Surface,Outdoor Air Drybulb Temperature,DF-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,DF-1
Actuator,Surface,Outdoor Air Wind Speed,DF-1
Actuator,Surface,Outdoor Air Wind Direction,DF-1
Actuator,Surface,View Factor To Ground,WF-1
Actuator,Surface,Outdoor Air Drybulb Temperature,WF-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,WF-1
Actuator,Surface,Outdoor Air Wind Speed,WF-1
Actuator,Surface,Outdoor Air Wind Direction,WF-1
Actuator,Surface,View Factor To Ground,RIGHT-1
Actuator,Surface,Outdoor Air Drybulb Temperature,RIGHT-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,RIGHT-1
Actuator,Surface,Outdoor Air Wind Speed,RIGHT-1
Actuator,Surface,Outdoor Air Wind Direction,RIGHT-1
Actuator,Surface,View Factor To Ground,WR-1
Actuator,Surface,Outdoor Air Drybulb Temperature,WR-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,WR-1
Actuator,Surface,Outdoor Air Wind Speed,WR-1
Actuator,Surface,Outdoor Air Wind Direction,WR-1
Actuator,Surface,View Factor To Ground,BACK-1
Actuator,Surface,Outdoor Air Drybulb Temperature,BACK-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,BACK-1
Actuator,Surface,Outdoor Air Wind Speed,BACK-1
Actuator,Surface,Outdoor Air Wind Direction,BACK-1
Actuator,Surface,View Factor To Ground,DB-1
Actuator,Surface,Outdoor Air Drybulb Temperature,DB-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,DB-1
Actuator,Surface,Outdoor Air Wind Speed,DB-1
Actuator,Surface,Outdoor Air Wind Direction,DB-1
Actuator,Surface,View Factor To Ground,WB-1
Actuator,Surface,Outdoor Air Drybulb Temperature,WB-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,WB-1
Actuator,Surface,Outdoor Air Wind Speed,WB-1
Actuator,Surface,Outdoor Air Wind Direction,WB-1
Actuator,Surface,View Factor To Ground,LEFT-1
Actuator,Surface,Outdoor Air Drybulb Temperature,LEFT-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,LEFT-1
Actuator,Surface,Outdoor Air Wind Speed,LEFT-1
Actuator,Surface,Outdoor Air Wind Direction,LEFT-1
Actuator,Surface,View Factor To Ground,WL-1
Actuator,Surface,Outdoor Air Drybulb Temperature,WL-1
Actuator,Surface,Outdoor Air Wetbulb Temperature,WL-1
Actuator,Surface,Outdoor Air Wind Speed,WL-1
Actuator,Surface,Outdoor Air Wind Direction,WL-1
Actuator,Zone,Outdoor Air Drybulb Temperature,PLENUM-1
Actuator,Zone,Outdoor Air Wetbulb Temperature,PLENUM-1
Actuator,Zone,Outdoor Air Wind Speed,PLENUM-1
Actuator,Zone,Outdoor Air Wind Direction,PLENUM-1
Actuator,Zone,Outdoor Air Drybulb Temperature,SPACE1-1
Actuator,Zone,Outdoor Air Wetbulb Temperature,SPACE1-1
Actuator,Zone,Outdoor Air Wind Speed,SPACE1-1
Actuator,Zone,Outdoor Air Wind Direction,SPACE1-1
Actuator,Zone,Outdoor Air Drybulb Temperature,SPACE2-1
Actuator,Zone,Outdoor Air Wetbulb Temperature,SPACE2-1
Actuator,Zone,Outdoor Air Wind Speed,SPACE2-1
Actuator,Zone,Outdoor Air Wind Direction,SPACE2-1
Actuator,Zone,Outdoor Air Drybulb Temperature,SPACE3-1
Actuator,Zone,Outdoor Air Wetbulb Temperature,SPACE3-1
Actuator,Zone,Outdoor Air Wind Speed,SPACE3-1
Actuator,Zone,Outdoor Air Wind Direction,SPACE3-1
Actuator,Zone,Outdoor Air Drybulb Temperature,SPACE4-1
Actuator,Zone,Outdoor Air Wetbulb Temperature,SPACE4-1
Actuator,Zone,Outdoor Air Wind Speed,SPACE4-1
Actuator,Zone,Outdoor Air Wind Direction,SPACE4-1
Actuator,Zone,Outdoor Air Drybulb Temperature,SPACE5-1
Actuator,Zone,Outdoor Air Wetbulb Temperature,SPACE5-1
Actuator,Zone,Outdoor Air Wind Speed,SPACE5-1
Actuator,Zone,Outdoor Air Wind Direction,SPACE5-1
Actuator,Zone Infiltration,Air Exchange Flow Rate,SPACE1-1 INFIL 1
Actuator,Zone Infiltration,Air Exchange Flow Rate,SPACE2-1 INFIL 1
Actuator,Zone Infiltration,Air Exchange Flow Rate,SPACE3-1 INFIL 1
Actuator,Zone Infiltration,Air Exchange Flow Rate,SPACE4-1 INFIL 1
Actuator,Zone Infiltration,Air Exchange Flow Rate,SPACE5-1 INFIL 1
Actuator,Sizing:Zone,Zone Design Heating Air Mass Flow Rate,SPACE1-1
Actuator,Sizing:Zone,Zone Design Cooling Air Mass Flow Rate,SPACE1-1
Actuator,Sizing:Zone,Zone Design Heating Load,SPACE1-1
Actuator,Sizing:Zone,Zone Design Cooling Load,SPACE1-1
Actuator,Sizing:Zone,Zone Design Heating Vol Flow,SPACE1-1
Actuator,Sizing:Zone,Zone Design Cooling Vol Flow,SPACE1-1
Actuator,Sizing:Zone,Zone Design Heating Air Mass Flow Rate,SPACE2-1
Actuator,Sizing:Zone,Zone Design Cooling Air Mass Flow Rate,SPACE2-1
Actuator,Sizing:Zone,Zone Design Heating Load,SPACE2-1
Actuator,Sizing:Zone,Zone Design Cooling Load,SPACE2-1
Actuator,Sizing:Zone,Zone Design Heating Vol Flow,SPACE2-1
Actuator,Sizing:Zone,Zone Design Cooling Vol Flow,SPACE2-1
Actuator,Sizing:Zone,Zone Design Heating Air Mass Flow Rate,SPACE3-1
Actuator,Sizing:Zone,Zone Design Cooling Air Mass Flow Rate,SPACE3-1
Actuator,Sizing:Zone,Zone Design Heating Load,SPACE3-1
Actuator,Sizing:Zone,Zone Design Cooling Load,SPACE3-1
Actuator,Sizing:Zone,Zone Design Heating Vol Flow,SPACE3-1
Actuator,Sizing:Zone,Zone Design Cooling Vol Flow,SPACE3-1
Actuator,Sizing:Zone,Zone Design Heating Air Mass Flow Rate,SPACE4-1
Actuator,Sizing:Zone,Zone Design Cooling Air Mass Flow Rate,SPACE4-1
Actuator,Sizing:Zone,Zone Design Heating Load,SPACE4-1
Actuator,Sizing:Zone,Zone Design Cooling Load,SPACE4-1
Actuator,Sizing:Zone,Zone Design Heating Vol Flow,SPACE4-1
Actuator,Sizing:Zone,Zone Design Cooling Vol Flow,SPACE4-1
Actuator,Sizing:Zone,Zone Design Heating Air Mass Flow Rate,SPACE5-1
Actuator,Sizing:Zone,Zone Design Cooling Air Mass Flow Rate,SPACE5-1
Actuator,Sizing:Zone,Zone Design Heating Load,SPACE5-1
Actuator,Sizing:Zone,Zone Design Cooling Load,SPACE5-1
Actuator,Sizing:Zone,Zone Design Heating Vol Flow,SPACE5-1
Actuator,Sizing:Zone,Zone Design Cooling Vol Flow,SPACE5-1
Actuator,Zone Temperature Control,Heating Setpoint,SPACE1-1
Actuator,Zone Temperature Control,Cooling Setpoint,SPACE1-1
Actuator,Zone Temperature Control,Heating Setpoint,SPACE2-1
Actuator,Zone Temperature Control,Cooling Setpoint,SPACE2-1
Actuator,Zone Temperature Control,Heating Setpoint,SPACE3-1
Actuator,Zone Temperature Control,Cooling Setpoint,SPACE3-1
Actuator,Zone Temperature Control,Heating Setpoint,SPACE4-1
Actuator,Zone Temperature Control,Cooling Setpoint,SPACE4-1
Actuator,Zone Temperature Control,Heating Setpoint,SPACE5-1
Actuator,Zone Temperature Control,Cooling Setpoint,SPACE5-1
Actuator,Fan,Fan Air Mass Flow Rate,SUPPLY FAN 1
Actuator,Fan,Fan Pressure Rise,SUPPLY FAN 1
Actuator,Fan,Fan Total Efficiency,SUPPLY FAN 1
Actuator,Fan,Fan Autosized Air Flow Rate,SUPPLY FAN 1
Actuator,Sizing:System,Main Supply Volume Flow Rate,VAV SYS 1
Actuator,Sizing:System,Main Supply Coincident Peak Cooling Mass Flow Rate,VAV SYS 1
Actuator,Sizing:System,Main Supply Coincident Peak Heating Mass Flow Rate,VAV SYS 1
Actuator,Sizing:System,Main Supply Noncoincident Peak Cooling Mass Flow Rate,VAV SYS 1
Actuator,Sizing:System,Main Supply Noncoincident Peak Heating Mass Flow Rate,VAV SYS 1
Actuator,Sizing:System,Main Heating Volume Flow Rate,VAV SYS 1
Actuator,Sizing:System,Main Cooling Volume Flow Rate,VAV SYS 1
Actuator,Outdoor Air Controller,Air Mass Flow Rate,OA CONTROLLER 1
Actuator,Curve,Curve Result,VARSPEEDCOOLCAPFT
Actuator,Curve,Curve Result,VARSPEEDCOOLCAPLSFT
Actuator,Curve,Curve Result,VARSPEEDCOOLEIRFT
Actuator,Curve,Curve Result,VARSPEEDCOOLEIRLSFT
Actuator,Curve,Curve Result,PACKAGEDRATEDCOOLCAPFFLOW
Actuator,Curve,Curve Result,PACKAGEDRATEDCOOLEIRFFLOW
Actuator,Curve,Curve Result,VARSPEEDCYCLINGPLFFPLR
Actuator,System Node Setpoint,Temperature Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Temperature Minimum Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Temperature Maximum Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Humidity Ratio Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,OUTSIDE AIR INLET NODE 1
Actuator,System Node Setpoint,Temperature Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE1-1 IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE2-1 IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE3-1 IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE4-1 IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE5-1 IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,VAV SYS 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Temperature Minimum Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Temperature Maximum Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Humidity Ratio Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,MIXED AIR NODE 1
Actuator,System Node Setpoint,Temperature Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,MAIN COOLING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,MAIN HEATING COIL 1 OUTLET NODE
Actuator,System Node Setpoint,Temperature Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,VAV SYS 1 INLET NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE1-1 NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE1-1 OUT NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE2-1 NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE2-1 OUT NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE3-1 NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE3-1 OUT NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE4-1 NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE4-1 OUT NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE5-1 NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE5-1 OUT NODE
Actuator,System Node Setpoint,Temperature Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,ZONE EQ IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,PLENUM-1 OUT NODE
Actuator,System Node Setpoint,Temperature Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE1-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE2-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE3-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE4-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE5-1 ATU IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE1-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE2-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE3-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE4-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,SPACE5-1 ZONE COIL AIR IN NODE
Actuator,System Node Setpoint,Temperature Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Temperature Minimum Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Temperature Maximum Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,PLENUM-1 NODE
Actuator,System Node Setpoint,Temperature Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Temperature Minimum Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Temperature Maximum Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Humidity Ratio Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Humidity Ratio Maximum Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Humidity Ratio Minimum Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Maximum Available Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,System Node Setpoint,Mass Flow Rate Minimum Available Setpoint,RELIEF AIR OUTLET NODE 1
Actuator,Outdoor Air System Node,Drybulb Temperature,OUTSIDE AIR INLET NODE 1
Actuator,Outdoor Air System Node,Wetbulb Temperature,OUTSIDE AIR INLET NODE 1
Actuator,Outdoor Air System Node,Wind Speed,OUTSIDE AIR INLET NODE 1
Actuator,Outdoor Air System Node,Wind Direction,OUTSIDE AIR INLET NODE 1
Actuator,Outdoor Air System Node,Drybulb Temperature,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,Outdoor Air System Node,Wetbulb Temperature,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,Outdoor Air System Node,Wind Speed,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,Outdoor Air System Node,Wind Direction,MAIN COOLING COIL 1 CONDENSER NODE
Actuator,AirLoopHVAC,Availability Status,VAV SYS 1
**INTERNAL_VARIABLES**
InternalVariable,People Count Design Level,SPACE1-1 PEOPLE 1
InternalVariable,People Count Design Level,SPACE2-1 PEOPLE 1
InternalVariable,People Count Design Level,SPACE3-1 PEOPLE 1
InternalVariable,People Count Design Level,SPACE4-1 PEOPLE 1
InternalVariable,People Count Design Level,SPACE5-1 PEOPLE 1
InternalVariable,Lighting Power Design Level,SPACE1-1 LIGHTS 1
InternalVariable,Lighting Power Design Level,SPACE2-1 LIGHTS 1
InternalVariable,Lighting Power Design Level,SPACE3-1 LIGHTS 1
InternalVariable,Lighting Power Design Level,SPACE4-1 LIGHTS 1
InternalVariable,Lighting Power Design Level,SPACE5-1 LIGHTS 1
InternalVariable,Plug and Process Power Design Level,SPACE1-1 ELECEQ 1
InternalVariable,Plug and Process Power Design Level,SPACE2-1 ELECEQ 1
InternalVariable,Plug and Process Power Design Level,SPACE3-1 ELECEQ 1
InternalVariable,Plug and Process Power Design Level,SPACE4-1 ELECEQ 1
InternalVariable,Plug and Process Power Design Level,SPACE5-1 ELECEQ 1
InternalVariable,Zone Floor Area,PLENUM-1
InternalVariable,Zone Air Volume,PLENUM-1
InternalVariable,Zone Multiplier,PLENUM-1
InternalVariable,Zone List Multiplier,PLENUM-1
InternalVariable,Zone Floor Area,SPACE1-1
InternalVariable,Zone Air Volume,SPACE1-1
InternalVariable,Zone Multiplier,SPACE1-1
InternalVariable,Zone List Multiplier,SPACE1-1
InternalVariable,Zone Floor Area,SPACE2-1
InternalVariable,Zone Air Volume,SPACE2-1
InternalVariable,Zone Multiplier,SPACE2-1
InternalVariable,Zone List Multiplier,SPACE2-1
InternalVariable,Zone Floor Area,SPACE3-1
InternalVariable,Zone Air Volume,SPACE3-1
InternalVariable,Zone Multiplier,SPACE3-1
InternalVariable,Zone List Multiplier,SPACE3-1
InternalVariable,Zone Floor Area,SPACE4-1
InternalVariable,Zone Air Volume,SPACE4-1
InternalVariable,Zone Multiplier,SPACE4-1
InternalVariable,Zone List Multiplier,SPACE4-1
InternalVariable,Zone Floor Area,SPACE5-1
InternalVariable,Zone Air Volume,SPACE5-1
InternalVariable,Zone Multiplier,SPACE5-1
InternalVariable,Zone List Multiplier,SPACE5-1
InternalVariable,Final Zone Design Heating Air Mass Flow Rate,SPACE1-1
InternalVariable,Intermediate Zone Design Heating Air Mass Flow Rate,SPACE1-1
InternalVariable,Final Zone Design Cooling Air Mass Flow Rate,SPACE1-1
InternalVariable,Intermediate Zone Design Cooling Air Mass Flow Rate,SPACE1-1
InternalVariable,Final Zone Design Heating Load,SPACE1-1
InternalVariable,Intermediate Zone Design Heating Load,SPACE1-1
InternalVariable,Final Zone Design Cooling Load,SPACE1-1
InternalVariable,Intermediate Zone Design Cooling Load,SPACE1-1
InternalVariable,Final Zone Design Heating Air Density,SPACE1-1
InternalVariable,Intermediate Zone Design Heating Air Density,SPACE1-1
InternalVariable,Final Zone Design Cooling Air Density,SPACE1-1
InternalVariable,Intermediate Zone Design Cooling Air Density,SPACE1-1
InternalVariable,Final Zone Design Heating Volume Flow,SPACE1-1
InternalVariable,Intermediate Zone Design Heating Volume Flow,SPACE1-1
InternalVariable,Final Zone Design Cooling Volume Flow,SPACE1-1
InternalVariable,Intermediate Zone Design Cooling Volume Flow,SPACE1-1
InternalVariable,Zone Outdoor Air Design Volume Flow Rate,SPACE1-1
InternalVariable,Final Zone Design Heating Air Mass Flow Rate,SPACE2-1
InternalVariable,Intermediate Zone Design Heating Air Mass Flow Rate,SPACE2-1
InternalVariable,Final Zone Design Cooling Air Mass Flow Rate,SPACE2-1
InternalVariable,Intermediate Zone Design Cooling Air Mass Flow Rate,SPACE2-1
InternalVariable,Final Zone Design Heating Load,SPACE2-1
InternalVariable,Intermediate Zone Design Heating Load,SPACE2-1
InternalVariable,Final Zone Design Cooling Load,SPACE2-1
InternalVariable,Intermediate Zone Design Cooling Load,SPACE2-1
InternalVariable,Final Zone Design Heating Air Density,SPACE2-1
InternalVariable,Intermediate Zone Design Heating Air Density,SPACE2-1
InternalVariable,Final Zone Design Cooling Air Density,SPACE2-1
InternalVariable,Intermediate Zone Design Cooling Air Density,SPACE2-1
InternalVariable,Final Zone Design Heating Volume Flow,SPACE2-1
InternalVariable,Intermediate Zone Design Heating Volume Flow,SPACE2-1
InternalVariable,Final Zone Design Cooling Volume Flow,SPACE2-1
InternalVariable,Intermediate Zone Design Cooling Volume Flow,SPACE2-1
InternalVariable,Zone Outdoor Air Design Volume Flow Rate,SPACE2-1
InternalVariable,Final Zone Design Heating Air Mass Flow Rate,SPACE3-1
InternalVariable,Intermediate Zone Design Heating Air Mass Flow Rate,SPACE3-1
InternalVariable,Final Zone Design Cooling Air Mass Flow Rate,SPACE3-1
InternalVariable,Intermediate Zone Design Cooling Air Mass Flow Rate,SPACE3-1
InternalVariable,Final Zone Design Heating Load,SPACE3-1
InternalVariable,Intermediate Zone Design Heating Load,SPACE3-1
InternalVariable,Final Zone Design Cooling Load,SPACE3-1
InternalVariable,Intermediate Zone Design Cooling Load,SPACE3-1
InternalVariable,Final Zone Design Heating Air Density,SPACE3-1
InternalVariable,Intermediate Zone Design Heating Air Density,SPACE3-1
InternalVariable,Final Zone Design Cooling Air Density,SPACE3-1
InternalVariable,Intermediate Zone Design Cooling Air Density,SPACE3-1
InternalVariable,Final Zone Design Heating Volume Flow,SPACE3-1
InternalVariable,Intermediate Zone Design Heating Volume Flow,SPACE3-1
InternalVariable,Final Zone Design Cooling Volume Flow,SPACE3-1
InternalVariable,Intermediate Zone Design Cooling Volume Flow,SPACE3-1
InternalVariable,Zone Outdoor Air Design Volume Flow Rate,SPACE3-1
InternalVariable,Final Zone Design Heating Air Mass Flow Rate,SPACE4-1
InternalVariable,Intermediate Zone Design Heating Air Mass Flow Rate,SPACE4-1
InternalVariable,Final Zone Design Cooling Air Mass Flow Rate,SPACE4-1
InternalVariable,Intermediate Zone Design Cooling Air Mass Flow Rate,SPACE4-1
InternalVariable,Final Zone Design Heating Load,SPACE4-1
InternalVariable,Intermediate Zone Design Heating Load,SPACE4-1
InternalVariable,Final Zone Design Cooling Load,SPACE4-1
InternalVariable,Intermediate Zone Design Cooling Load,SPACE4-1
InternalVariable,Final Zone Design Heating Air Density,SPACE4-1
InternalVariable,Intermediate Zone Design Heating Air Density,SPACE4-1
InternalVariable,Final Zone Design Cooling Air Density,SPACE4-1
InternalVariable,Intermediate Zone Design Cooling Air Density,SPACE4-1
InternalVariable,Final Zone Design Heating Volume Flow,SPACE4-1
InternalVariable,Intermediate Zone Design Heating Volume Flow,SPACE4-1
InternalVariable,Final Zone Design Cooling Volume Flow,SPACE4-1
InternalVariable,Intermediate Zone Design Cooling Volume Flow,SPACE4-1
InternalVariable,Zone Outdoor Air Design Volume Flow Rate,SPACE4-1
InternalVariable,Final Zone Design Heating Air Mass Flow Rate,SPACE5-1
InternalVariable,Intermediate Zone Design Heating Air Mass Flow Rate,SPACE5-1
InternalVariable,Final Zone Design Cooling Air Mass Flow Rate,SPACE5-1
InternalVariable,Intermediate Zone Design Cooling Air Mass Flow Rate,SPACE5-1
InternalVariable,Final Zone Design Heating Load,SPACE5-1
InternalVariable,Intermediate Zone Design Heating Load,SPACE5-1
InternalVariable,Final Zone Design Cooling Load,SPACE5-1
InternalVariable,Intermediate Zone Design Cooling Load,SPACE5-1
InternalVariable,Final Zone Design Heating Air Density,SPACE5-1
InternalVariable,Intermediate Zone Design Heating Air Density,SPACE5-1
InternalVariable,Final Zone Design Cooling Air Density,SPACE5-1
InternalVariable,Intermediate Zone Design Cooling Air Density,SPACE5-1
InternalVariable,Final Zone Design Heating Volume Flow,SPACE5-1
InternalVariable,Intermediate Zone Design Heating Volume Flow,SPACE5-1
InternalVariable,Final Zone Design Cooling Volume Flow,SPACE5-1
InternalVariable,Intermediate Zone Design Cooling Volume Flow,SPACE5-1
InternalVariable,Zone Outdoor Air Design Volume Flow Rate,SPACE5-1
InternalVariable,Fan Maximum Mass Flow Rate,SUPPLY FAN 1
InternalVariable,Fan Nominal Pressure Rise,SUPPLY FAN 1
InternalVariable,Fan Nominal Total Efficiency,SUPPLY FAN 1
InternalVariable,Intermediate Air System Main Supply Volume Flow Rate,VAV SYS 1
InternalVariable,Intermediate Air System Coincident Peak Cooling Mass Flow Rate,VAV SYS 1
InternalVariable,Intermediate Air System Coincident Peak Heating Mass Flow Rate,VAV SYS 1
InternalVariable,Intermediate Air System Noncoincident Peak Cooling Mass Flow Rate,VAV SYS 1
InternalVariable,Intermediate Air System Noncoincident Peak Heating Mass Flow Rate,VAV SYS 1
InternalVariable,Intermediate Air System Heating Volume Flow Rate,VAV SYS 1
InternalVariable,Intermediate Air System Cooling Volume Flow Rate,VAV SYS 1
InternalVariable,Air System Cooling Design Sensible Capacity,VAV SYS 1
InternalVariable,Air System Cooling Design Total Capacity,VAV SYS 1
InternalVariable,Air System Heating Design Sensible Capacity,VAV SYS 1
InternalVariable,Air System Preheating Design Sensible Capacity,VAV SYS 1
InternalVariable,Air System Outdoor Air Design Volume Flow Rate,VAV SYS 1
InternalVariable,Air System Cooling Design Mixed Air Temperature,VAV SYS 1
InternalVariable,Air System Cooling Design Mixed Air Humidity Ratio,VAV SYS 1
InternalVariable,Air System Cooling Design Return Air Temperature,VAV SYS 1
InternalVariable,Air System Cooling Design Return Air Humidity Ratio,VAV SYS 1
InternalVariable,Air System Cooling Design Outdoor Air Temperature,VAV SYS 1
InternalVariable,Air System Cooling Design Outdoor Air Humidity Ratio,VAV SYS 1
InternalVariable,Air System Heating Design Mixed Air Temperature,VAV SYS 1
InternalVariable,Air System Heating Design Mixed Air Humidity Ratio,VAV SYS 1
InternalVariable,Air System Heating Design Return Air Temperature,VAV SYS 1
InternalVariable,Air System Heating Design Return Air Humidity Ratio,VAV SYS 1
InternalVariable,Air System Heating Design Outdoor Air Temperature,VAV SYS 1
InternalVariable,Air System Heating Design Outdoor Air Humidity Ratio,VAV SYS 1
InternalVariable,Outdoor Air Controller Maximum Mass Flow Rate,OA CONTROLLER 1
InternalVariable,Outdoor Air Controller Minimum Mass Flow Rate,OA CONTROLLER 1
**PLUGIN_GLOBAL_VARIABLES**
**TRENDS**
**METERS**
OutputMeter,Electricity:Facility
OutputMeter,Electricity:Building
OutputMeter,Electricity:Zone:SPACE1-1
OutputMeter,Electricity:SpaceType:GENERAL
OutputMeter,InteriorLights:Electricity
OutputMeter,InteriorLights:Electricity:Zone:SPACE1-1
OutputMeter,InteriorLights:Electricity:SpaceType:GENERAL
OutputMeter,GeneralLights:InteriorLights:Electricity
OutputMeter,GeneralLights:InteriorLights:Electricity:Zone:SPACE1-1
OutputMeter,GeneralLights:InteriorLights:Electricity:SpaceType:GENERAL
OutputMeter,Electricity:Zone:SPACE2-1
OutputMeter,InteriorLights:Electricity:Zone:SPACE2-1
OutputMeter,GeneralLights:InteriorLights:Electricity:Zone:SPACE2-1
OutputMeter,Electricity:Zone:SPACE3-1
OutputMeter,InteriorLights:Electricity:Zone:SPACE3-1
OutputMeter,GeneralLights:InteriorLights:Electricity:Zone:SPACE3-1
OutputMeter,Electricity:Zone:SPACE4-1
OutputMeter,InteriorLights:Electricity:Zone:SPACE4-1
OutputMeter,GeneralLights:InteriorLights:Electricity:Zone:SPACE4-1
OutputMeter,Electricity:Zone:SPACE5-1
OutputMeter,InteriorLights:Electricity:Zone:SPACE5-1
OutputMeter,GeneralLights:InteriorLights:Electricity:Zone:SPACE5-1
OutputMeter,InteriorEquipment:Electricity
OutputMeter,InteriorEquipment:Electricity:Zone:SPACE1-1
OutputMeter,InteriorEquipment:Electricity:SpaceType:GENERAL
OutputMeter,General:InteriorEquipment:Electricity
OutputMeter,General:InteriorEquipment:Electricity:Zone:SPACE1-1
OutputMeter,General:InteriorEquipment:Electricity:SpaceType:GENERAL
OutputMeter,InteriorEquipment:Electricity:Zone:SPACE2-1
OutputMeter,General:InteriorEquipment:Electricity:Zone:SPACE2-1
OutputMeter,InteriorEquipment:Electricity:Zone:SPACE3-1
OutputMeter,General:InteriorEquipment:Electricity:Zone:SPACE3-1
OutputMeter,InteriorEquipment:Electricity:Zone:SPACE4-1
OutputMeter,General:InteriorEquipment:Electricity:Zone:SPACE4-1
OutputMeter,InteriorEquipment:Electricity:Zone:SPACE5-1
OutputMeter,General:InteriorEquipment:Electricity:Zone:SPACE5-1
OutputMeter,EnergyTransfer:Facility
OutputMeter,EnergyTransfer:Building
OutputMeter,EnergyTransfer:Zone:PLENUM-1
OutputMeter,Heating:EnergyTransfer
OutputMeter,Heating:EnergyTransfer:Zone:PLENUM-1
OutputMeter,General:Heating:EnergyTransfer
OutputMeter,General:Heating:EnergyTransfer:Zone:PLENUM-1
OutputMeter,Cooling:EnergyTransfer
OutputMeter,Cooling:EnergyTransfer:Zone:PLENUM-1
OutputMeter,General:Cooling:EnergyTransfer
OutputMeter,General:Cooling:EnergyTransfer:Zone:PLENUM-1
OutputMeter,EnergyTransfer:Zone:SPACE1-1
OutputMeter,Heating:EnergyTransfer:Zone:SPACE1-1
OutputMeter,General:Heating:EnergyTransfer:Zone:SPACE1-1
OutputMeter,Cooling:EnergyTransfer:Zone:SPACE1-1
OutputMeter,General:Cooling:EnergyTransfer:Zone:SPACE1-1
OutputMeter,EnergyTransfer:Zone:SPACE2-1
OutputMeter,Heating:EnergyTransfer:Zone:SPACE2-1
OutputMeter,General:Heating:EnergyTransfer:Zone:SPACE2-1
OutputMeter,Cooling:EnergyTransfer:Zone:SPACE2-1
OutputMeter,General:Cooling:EnergyTransfer:Zone:SPACE2-1
OutputMeter,EnergyTransfer:Zone:SPACE3-1
OutputMeter,Heating:EnergyTransfer:Zone:SPACE3-1
OutputMeter,General:Heating:EnergyTransfer:Zone:SPACE3-1
OutputMeter,Cooling:EnergyTransfer:Zone:SPACE3-1
OutputMeter,General:Cooling:EnergyTransfer:Zone:SPACE3-1
OutputMeter,EnergyTransfer:Zone:SPACE4-1
OutputMeter,Heating:EnergyTransfer:Zone:SPACE4-1
OutputMeter,General:Heating:EnergyTransfer:Zone:SPACE4-1
OutputMeter,Cooling:EnergyTransfer:Zone:SPACE4-1
OutputMeter,General:Cooling:EnergyTransfer:Zone:SPACE4-1
OutputMeter,EnergyTransfer:Zone:SPACE5-1
OutputMeter,Heating:EnergyTransfer:Zone:SPACE5-1
OutputMeter,General:Heating:EnergyTransfer:Zone:SPACE5-1
OutputMeter,Cooling:EnergyTransfer:Zone:SPACE5-1
OutputMeter,General:Cooling:EnergyTransfer:Zone:SPACE5-1
OutputMeter,ElectricityPurchased:Facility
OutputMeter,ElectricityPurchased:Plant
OutputMeter,Cogeneration:ElectricityPurchased
OutputMeter,General:Cogeneration:ElectricityPurchased
OutputMeter,ElectricitySurplusSold:Facility
OutputMeter,ElectricitySurplusSold:Plant
OutputMeter,Cogeneration:ElectricitySurplusSold
OutputMeter,General:Cogeneration:ElectricitySurplusSold
OutputMeter,ElectricityNet:Facility
OutputMeter,ElectricityNet:Plant
OutputMeter,Cogeneration:ElectricityNet
OutputMeter,General:Cogeneration:ElectricityNet
OutputMeter,EnergyTransfer:HVAC
OutputMeter,HeatingCoils:EnergyTransfer
OutputMeter,Electricity:HVAC
OutputMeter,Heating:Electricity
OutputMeter,General:Heating:Electricity
OutputMeter,Fans:Electricity
OutputMeter,General:Fans:Electricity
OutputMeter,CoolingCoils:EnergyTransfer
OutputMeter,Cooling:Electricity
OutputMeter,General:Cooling:Electricity
OutputMeter,Water:Facility
OutputMeter,Water:HVAC
OutputMeter,Cooling:Water
OutputMeter,General:Cooling:Water
OutputMeter,MainsWater:Facility
OutputMeter,MainsWater:HVAC
OutputMeter,Cooling:MainsWater
OutputMeter,General:Cooling:MainsWater
OutputMeter,Carbon Equivalent:Facility
OutputMeter,CarbonEquivalentEmissions:Carbon Equivalent
**VARIABLES**
OutputVariable,Site Outdoor Air Drybulb Temperature,ENVIRONMENT
OutputVariable,Lights Electricity Energy,SPACE1-1 LIGHTS 1
OutputVariable,Lights Electricity Energy,SPACE2-1 LIGHTS 1
OutputVariable,Lights Electricity Energy,SPACE3-1 LIGHTS 1
OutputVariable,Lights Electricity Energy,SPACE4-1 LIGHTS 1
OutputVariable,Lights Electricity Energy,SPACE5-1 LIGHTS 1
OutputVariable,Electric Equipment Electricity Energy,SPACE1-1 ELECEQ 1
OutputVariable,Electric Equipment Electricity Energy,SPACE2-1 ELECEQ 1
OutputVariable,Electric Equipment Electricity Energy,SPACE3-1 ELECEQ 1
OutputVariable,Electric Equipment Electricity Energy,SPACE4-1 ELECEQ 1
OutputVariable,Electric Equipment Electricity Energy,SPACE5-1 ELECEQ 1
OutputVariable,Zone Air System Sensible Heating Energy,PLENUM-1
OutputVariable,Zone Air System Sensible Cooling Energy,PLENUM-1
OutputVariable,Zone Air System Sensible Heating Energy,SPACE1-1
OutputVariable,Zone Air System Sensible Cooling Energy,SPACE1-1
OutputVariable,Zone Air System Sensible Heating Energy,SPACE2-1
OutputVariable,Zone Air System Sensible Cooling Energy,SPACE2-1
OutputVariable,Zone Air System Sensible Heating Energy,SPACE3-1
OutputVariable,Zone Air System Sensible Cooling Energy,SPACE3-1
OutputVariable,Zone Air System Sensible Heating Energy,SPACE4-1
OutputVariable,Zone Air System Sensible Cooling Energy,SPACE4-1
OutputVariable,Zone Air Temperature,SPACE5-1
OutputVariable,Zone Air Relative Humidity,SPACE5-1
OutputVariable,Zone Air System Sensible Heating Energy,SPACE5-1
OutputVariable,Zone Air System Sensible Cooling Energy,SPACE5-1
OutputVariable,Zone Thermostat Heating Setpoint Temperature,SPACE5-1
OutputVariable,Zone Thermostat Cooling Setpoint Temperature,SPACE5-1
OutputVariable,Facility Total Purchased Electricity Energy,WHOLE BUILDING
OutputVariable,Facility Total Surplus Electricity Energy,WHOLE BUILDING
OutputVariable,Facility Net Purchased Electricity Energy,WHOLE BUILDING
OutputVariable,Facility Total HVAC Electricity Demand Rate,WHOLE BUILDING
OutputVariable,Heating Coil Heating Energy,MAIN HEATING COIL 1
OutputVariable,Heating Coil Electricity Energy,MAIN HEATING COIL 1
OutputVariable,Heating Coil Heating Energy,SPACE1-1 ZONE COIL
OutputVariable,Heating Coil Electricity Energy,SPACE1-1 ZONE COIL
OutputVariable,Heating Coil Heating Energy,SPACE2-1 ZONE COIL
OutputVariable,Heating Coil Electricity Energy,SPACE2-1 ZONE COIL
OutputVariable,Heating Coil Heating Energy,SPACE3-1 ZONE COIL
OutputVariable,Heating Coil Electricity Energy,SPACE3-1 ZONE COIL
OutputVariable,Heating Coil Heating Energy,SPACE4-1 ZONE COIL
OutputVariable,Heating Coil Electricity Energy,SPACE4-1 ZONE COIL
OutputVariable,Heating Coil Heating Energy,SPACE5-1 ZONE COIL
OutputVariable,Heating Coil Electricity Energy,SPACE5-1 ZONE COIL
OutputVariable,Fan Electricity Energy,SUPPLY FAN 1
OutputVariable,Cooling Coil Total Cooling Energy,MAIN COOLING COIL 1
OutputVariable,Cooling Coil Electricity Energy,MAIN COOLING COIL 1
OutputVariable,Cooling Coil Evaporative Condenser Water Volume,MAIN COOLING COIL 1
OutputVariable,Cooling Coil Evaporative Condenser Mains Supply Water Volume,MAIN COOLING COIL 1
OutputVariable,Cooling Coil Evaporative Condenser Pump Electricity Energy,MAIN COOLING COIL 1
OutputVariable,Cooling Coil Basin Heater Electricity Energy,MAIN COOLING COIL 1
OutputVariable,Environmental Impact Total N2O Emissions Carbon Equivalent Mass,SITE
OutputVariable,Environmental Impact Total CH4 Emissions Carbon Equivalent Mass,SITE
OutputVariable,Environmental Impact Total CO2 Emissions Carbon Equivalent Mass,SITE
Controlled actuators: {'Heating_Setpoint_RL': 10, 'Cooling_Setpoint_RL': 5}
Observed variables: {'outdoor_temperature': 0, 'htg_setpoint': 25, 'clg_setpoint': 26, 'air_temperature': 21, 'air_humidity': 22, 'HVAC_electricity_demand_rate': 30}
Observed meters: {}
Displaying all the environment information
You can also print all the environment information. Just remember to do reset
beforehand to obtain handlers information too:
[7]:
env.get_wrapper_attr('to_str')()
#==================================================================================#
ENVIRONMENT NAME: demo-v1
#==================================================================================#
#----------------------------------------------------------------------------------#
ENVIRONMENT INFO:
#----------------------------------------------------------------------------------#
- Building file: /workspaces/sinergym/sinergym/data/buildings/5ZoneAutoDXVAV.epJSON
- Zone names: ['PLENUM-1', 'SPACE1-1', 'SPACE2-1', 'SPACE3-1', 'SPACE4-1', 'SPACE5-1']
- Weather file(s): USA_PA_Pittsburgh-Allegheny.County.AP.725205_TMY3.epw
- Current weather used: /workspaces/sinergym/sinergym/data/weather/USA_PA_Pittsburgh-Allegheny.County.AP.725205_TMY3.epw
- Episodes executed: 1
- Workspace directory: /workspaces/sinergym/examples/demo-v1-res1
- Reward function: <sinergym.utils.rewards.LinearReward object at 0x7f3d1b0bc980>
- Reset default options: {}
- Run period: {'start_day': 1, 'start_month': 1, 'start_year': 1991, 'end_day': 1, 'end_month': 3, 'end_year': 1991, 'start_weekday': 1, 'n_steps_per_hour': 1}
- Episode length (seconds): 5184000.0
- Number of timesteps in an episode: 1440
- Timestep size (seconds): 3600.0
- It is discrete?: False
- seed: None
#----------------------------------------------------------------------------------#
ENVIRONMENT SPACE:
#----------------------------------------------------------------------------------#
- Observation space: Box(-50000000.0, 50000000.0, (9,), float32)
- Observation variables: ['month', 'day_of_month', 'hour', 'outdoor_temperature', 'htg_setpoint', 'clg_setpoint', 'air_temperature', 'air_humidity', 'HVAC_electricity_demand_rate']
- Action space: Box([15. 22.5], [22.5 30. ], (2,), float32)
- Action variables: ['Heating_Setpoint_RL', 'Cooling_Setpoint_RL']
#==================================================================================#
SIMULATOR
#==================================================================================#
*NOTE: To have information about available handlers and controlled elements, it is
required to do env reset before to print information.*
Is running? : True
#----------------------------------------------------------------------------------#
AVAILABLE ELEMENTS:
#----------------------------------------------------------------------------------#
*Some variables cannot be here depending if it is defined Output:Variable field
in building model. See documentation for more information.*
#----------------------------------------------------------------------------------#
CONTROLLED ELEMENTS:
#----------------------------------------------------------------------------------#
- Actuators: {'Heating_Setpoint_RL': 10, 'Cooling_Setpoint_RL': 5}
- Variables: {'outdoor_temperature': 0, 'htg_setpoint': 25, 'clg_setpoint': 26, 'air_temperature': 21, 'air_humidity': 22, 'HVAC_electricity_demand_rate': 30}
- Meters: {}
- Internal Context: {}