Extra configuration in Sinergym simulations
Using the Modeling class, it is possible to set up some context details of the simulation. This allows us to expand the context of each experiment with additional parameters. You can provide these extra configuration to the environment constructor as follows:
import gymnasium as gym
import sinergym
extra_params={'timesteps_per_hour' : 6
'runperiod' : (1,1,1997,12,3,1998)}
env = gym.make('Eplus-5Zone-hot-continuous-v1', config_params=extra_params)
The format of these extra configuration parameters is a Python dictionary with their corresponding keys and values.
Let’s examine each parameter separately.
timestep_per_hour
By default, Sinergym applies 4 timesteps per simulated hour, which is the default value in building files.
However, you can modify this value using the timestep_per_hour
key in the config_params
dictionary and vary the number of timesteps in each simulated hour.
runperiod
By default, a Sinergym simulation episode lasts a single year (from 1/1/1991 to 31/12/1991). You can use the runperiod
key to determine the episode length in the simulation. The format value for the runperiod
key is a tuple with
(start_day
, start_month
, start_year
, end_day
, end_month
, end_year
).
Warning
If you include a manual runperiod
, make sure not to include
February 29th of a leap year in that range. Otherwise, the simulator will fail, as
EnergyPlus does not account for leap days and the weather files do not include these days.
Note
If you wish to create your own extra configuration parameters, refer to the method
apply_extra_conf