13. Extra Configuration in Sinergym simulations

With the Modeling class, we have the ability to set up some context details in our simulation. This allows us to expand the context of each experiment and investigate more parameters. To use this functionality easily, you can provide these extra parameters in the environment constructor as follows:

import gymnasium as gym
import sinergym

extra_params={'timesteps_per_hour' : 6
              'runperiod' : (1,1,1997,12,3,1998)}
env = gym.make('Eplus-5Zone-hot-continuous-v1', config_params=extra_params)

The format for applying extra configuration is a Python dictionary with the extra parameter key name and its value.

Note

Currently, only code skeleton and some parameters has been designed. Stay tuned for upcoming releases!

Let’s examine each implemented parameter for extra configuration separately:

13.1. timestep_per_hour

By default, Sinergym applies 4 timesteps per simulation hour, which is the default value in building files. However, you can modify this value using the timestep_per_hour key in the config_params dictionary and set more or fewer timesteps in each simulation hour.

13.2. runperiod

By default, a Sinergym simulation episode lasts one year (from 1/1/1991 to 31/12/1991). You can use the runperiod key to determine the episode length in the simulation. The format value for the runperiod key is a tuple with (start_day, start_month, start_year, end_day, end_month, end_year).

Warning

If you include a manual runperiod with this functionality, make sure not to include February 29th of a leap year in that range. Otherwise, the simulator will fail, as EnergyPlus does not account for leap days and the weather files do not include these days.

Note

More components may be managed in the future. Keep an eye out for upcoming releases!

Note

If you wish to create your own extra configuration parameters, refer to the method apply_extra_conf in the Modeling class.